Rule 01
Interference Transfer & Bore Closure
The bore closes when you press the bushing in. For a thin-wall bushing pressed into a rigid housing, roughly 70–90% of the diametral interference transfers to the bore.
Solution: Either pre-oversize the bore by this amount, or ream/bore to finished size after fitting. The latter is Allstar’s recommended practice for ≤ 0.05 mm running clearance.